Home > Diesel Generators > Diesel Generators > 50Hz > 0-20 kVA

TYM16

 

Introduction

Heavy duty, water cooled diesel engine Radiator with mechanical fan Protective grille for rotating and hot parts Electric starter and charge alternator Starting battery (with lead acid) including rack and cables Engine coolant heater Steel base frame and anti-vibration isolators Spare external fuel tank (open set) Flexible fuel connection hoses Two bearing, class H alternator Industrial exhaust silencer and steel bellows supplied separately Static battery charger Manual for application and installation

ISO 9001           This generator set is manufactured in facilities certified with ISO 9001.
                This generator set is available with CE certification. 

 

3 Phase Ratings, 50 Hz, PF 0,8

 Voltage  Standby Rating (ESP)  Prime Rating (PRP)
 kVA  kW  kVA  kW  Amp
 400/230 17.6 14 16 12.8 23.1

 

Standby Rating (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.

Prime Rating (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

 

Diesel Engine Specifications

 Manufacturer Yanmar
 Model 3TNV84T-GGE 
 No. of Cylinders and Build  3 Cylinder, In Line                      
 Aspiration and Cooling Turbocharged
 Maximum Standby Power

1500 rpm             

17.4 kW [23.3 HP]
 Total Displacement  L 1.496
 Bore and Stroke  mm  84x90
 Compression Ratio 19:1
 Rated Speed (rpm) rpm   1500
 Governor  Mechanical
 Oil Capacity  L 2.8-6.7
 Coolant Capacity 2 
 Intake Air Flow m³ /min.   2.9
 Radiator Cooling Air m³ /min.   53
 Exhaust Gas Flow  m³ /min.  7
 Start System  12
 Fuel Consumption  %100 (L/h) 5.0
 

Alternator Specifications

Make Leroy Somer
Frequency  Hz  50
Design  Brushless, 2 poles
Phase  3
Voltage  V  400/230
Current  A  0
Insulation Class  H
 

Dimensions and Weight

 Open Type

 Dry Weight
(kg.)

Lenght
(mm.)

 Width
(mm.)

 Height
(mm.)

 Tank Capacity (L)

380

1350

 620

 1280

 -

 Canopy

 Dry Weight
(kg.)

 Lenght
(mm.)

  Width
(mm.)

 Height
(mm.)

 Tank Capacity (L)

 1220

2250

 1000

 1200

 -

 

Standard Specifications

Heavy duty, water cooled diesel engine
- Radiator with mechanical fan
- Protective grille for rotating and hot parts
- Electric starter and charge alternator
- Starting battery (with lead acid) including rack and cables
- Engine coolant heater
- Steel base frame and anti-vibration isolators
- Spare external fuel tank (open set)
- Flexible fuel connection hoses
- Two bearing, class H alternator
- Industrial exhaust silencer and steel bellows supplied separately
- Static battery charger
- Manual for application and installation
 

Tide Easycon

 

     

TIDE Easycon Control Systems

TIDE Power comprehensive Easycon range control panels are compact, versatile and easy to use.

 

Easycon 2.0L/H (GU601A / Deepsea DSE3110) panel is a key-start auto control panel, it’s a basic control panel fits for  generators up to 100kVA to provide basic operating parameters display and protection.  

Specifications

- Over Speed pre-alarm & shutdown
- Low Oil Pressure Pre-Alarm & shutdown
- High Water Temp. Pre-alarm & shutdown
- Volts, Current, Frequency, Rpm (Instruments)
- Fuel Sensor as optional
- AMF Module as optional

- Auto Start
- Oil Pressure
- Genset Running Hours
- Battery Voltage and Charging                            

 

Options

Easycon 5.0H (Deepsea DSE8610) panel fits for Gen-Gen automatic Synchronising and load sharing.

Easycon 6.0H (Deepsea DSE8620) panel fits for Single Gen - Mains automatic Synchronising.

 

Deepsea DSE7560 Synchronising Controller for Multi gen – Mains Synchronising. This is a separate control unit which enables multiple Easycon 5.0 equipped Gens to be synchronised with the Mains supply.

  (For details specifications of Control Panels,please consult our sale department.)

 

Canopy

 
  •  

     

Introduction

Sound–attenuated and Weather-protective Enclosures:  Sound-attenuated and weather protective enclosures for generating sets from Tide Power, meet every sound level requirements and provide optimum protection from inclement weather and are developed and designed by our special acoustic engineers. Our modular designed and sound insulated canopies provide ease of access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance, providing you with confidence for genset ratings and ambient capability.

Standard Specifications

- Compact footprint, low profile design. 
- Enclosure, generator set, exhaust system and fuel tank are pre-ssembled, pre-integrated and shipped as one package 
- Body made from steel components treated with polyester powder coating 
- Fire retardant foam insulation 
- Easy access to all service points 
- Exhaust system inside canopy 
- Large doors on each side 
- Control panel viewing window in a access door 
- Emergency stop push button mounted on enclosure exterior 
- Cooling fan and battery charging alternator fully guarded 
- Fuel fill and battery can only be reached via access doors. 
- Lifting points on the base frame 
- Customer options available to meet your applications needs.